Sure-Check™ Sterilization Pouches (Steam)

CDC infection control guidelines make it clear – the only way to be sure an instrument has been sterilized is to expose it to all three sterilization criteria: time, temperature and steam. Multi-variable indicators are designed to react to two or more of the critical variables and are intended to indicate exposure to a sterilization cycle at a stated value of the chosen variable. Yet traditional sterilization pouches have an internal and/or external process indicator that reacts only to temperature.

Sure-Check® Sterilization Pouches feature internal/external multi-variable indicator technology that confirms all three criteria for sterilization have been met.

For CDC compliance, today more than ever, you need to be sure about sterilization – you need Sure-Check®.

  • Meets CDC Guidelines for Disinfection and Sterilization in Healthcare Facilities, 2008
  • Tested and certified by an independent laboratory
  • When used in conjunction with weekly biological monitoring, provides the highest level of sterility assurance, unlike traditional sterilization pouches with process indicators that measure only temperature
  • Meets ANSI/AAMI ST79 Comprehensive Guide to Steam Sterilization and Assurance in Health Care Facilities
  • Eliminates the extra step of adding separate multi-variable internal indicators to each pouch
Ref # Description Quantity
SCXX2 2.25” x 4” (6 x 10 cm) 200/ Box, 20/ Case
SCX2 2.75” x 9” (7 x 23 cm) 200/ Box, 20/ Case
SCXS2 3.5” x 5.25” (9 x 13 cm 200/ Box, 10/ Case
SCS2 3.5” x 9” (9 x 23 cm) 200/ Box, 20/ Case
SCS25 3.5” x 9” (9 x 23 cm) 500/ Box, 10/ Case
SCL3222 3.5” x 22” (9 x 56 cm) 100/ Box, 5/ Case
SCW2 5.25” x 6.5” (13 x 17 cm) 200/ Box, 10/ Case
SCM2 5.25” x 10” (13 x 25 cm) 200/ Box, 10/ Case
SCL5152 5.25” x 15” (13 x 38 cm) 200/ Box, 10/ Case
SCL2 7.5” x 13” (19 x 33 cm) 200/ Box, 5/ Case
SCL8162 8” x 16” (20 x 41 cm) 200/ Box, 5/ Case
SCL10152 10” x 15” (25 x 38 cm) 100/ Box, 5/ Case
SCL10172 10.5” x 17” (27 x 43 cm) 100/ Box, 5/ Case
SCL12152 12” x 15” (30 x 38 cm) 100/ Box, 5/ Case
SCL12182 12” x 18” (30 x 46 cm) 100/ Box, 5/ Case

No information to show.

  • 1
Showing 0 - 0 of 0
Failed Spore Test- What do you do?
  • 1
Showing 0 - 0 of 0

No information to show.

Process Steam / EO
Packaging Materials Paper – 60gsm Medical Grade Paper (55%)
Plastic – 2mL Polyester Cast Polypropylene (45%) (Clear)
Adhesive Tape – ½ mil polyester film coated sides with 1.4 mils of high tack, shear acrylic adhesive that exhibits good temperature resistance.
Indicators – Internal/External printed directly on pouch
Compliance Meets CDC Guidelines for Disinfection and Sterilization in Healthcare Facilities, 2008

Meets ANSI/AAMI ST79 Comprehensive Guide to Steam Sterilization and Assurance in Health Care Facilities

Shelf Life When properly sealed, sterility is maintained up to (3) three years provided the integrity of the pouch has not been compromised; i. e. pouch becomes wet, damaged or open during storage. Caution – Wet pouches may not preserve sterility of contents.
Storage Conditions  Store in a cool, dry place